Refrigerant Tanks: DOT Refrigerant Tanks, ASME Refrigerant Tanks
 |
ASME Tanks
High capacity storage tanks accept
complete high or low pressure refrigerant charges from large chillers.
NEW sight glass windows
replace sight glass tube (3/2003) |
 |
DOT
Tanks
30, 50, 250, & 1000-lb capacities.
Optional low pressure switches available. 250 & 1000-lb tanks are
retrofitted with full 3/4" service valves & copper dip tubes to meet capacity of
commercial recovery units. |
| l |
Mounted on casters |
| l |
High pressure (-HP) tanks: Dual
250-psi relief valves on diverting valve
Low pressure (-LP) tanks: 250-psi rupture disc & 250-psi relief (meets
ASME section VIII div 1 and ANSI specifications) |
| l |
Pressure gauge |
| l |
Three sight glass
windows |
| l |
80% tank full float switch |
| l |
Bottom drain connection |
| l |
Liquid & Vapor ports:
Threaded connections with isolation ball valves are supplied standard. Ball valves may be
substituted with quick connect fittings on LP tanks only. 3/4 connections accomodate
Lovac, Allvac, or Evac Commercial recovery units. |
| l |
Options:
- Cable for Liquid level cut out switch
- Heating Bands for distillation |
| part
number |
capacity |
ports
size/connections |
pressure |
length |
height |
width |
| ASME-250-075-HP |
250-gal |
3/4" flare w/ball valves |
high |
94-in |
42-in |
30-in |
| ASME-250-075-LP |
250-gal |
3/4" flare w/ball valves |
low |
94-in |
42-in |
30-in |
| ASME-250-075-LP-QC |
250-gal |
3/4" flare w/quick connects |
low |
94-in |
42-in |
30-in |
| ASME-500-075-HP |
500-gal |
3/4" flare w/ball valves |
high |
113-in |
49-in |
37-in |
| ASME-500-075-LP |
500-gal |
3/4" flare w/ball valves |
low |
113-in |
49-in |
37-in |
| ASME-500-075-LP-QC |
500-gal |
3/4" flare w/quick connects |
low |
113-in |
49-in |
37-in |
ASME Tank Refrigerant Capacity at 80%
(in pounds):
| tank model |
capacity |
dry weight |
R12 |
R22 |
R500 |
R502 |
R134A |
R11 |
R123 |
| ASME 250 |
250-gal |
650-LB |
2195 |
2000 |
2034 |
2039 |
2015 |
2459 |
2440 |
| ASME 500 |
500-gal |
1200-LB |
4390 |
4000 |
4068 |
4078 |
4030 |
4918 |
4880 |
| l |
Typical recovery tanks have
small diameter ports that restrict refrigerant flow and decrease recovery rates. RefTec
250 & 1000-lb D.O.T. tanks have been fitted with full 3/4 service valves and
copper dip tubes to eliminate restrictions and allow faster refrigerant transfer.
|
| l |
Tanks service R11, R12, R22,
R113, R114, R123, R134a, & and additional high pressure refrigerants and blends.
For R410a, use only 30 & 50-lb tanks. |
| l |
Quick connects are available for
tanks servicing low pressure refrigerants. |
| l |
Heating bands are available for
distillation capabilities |
| part number |
description |
port size
(inch) |
dry weight
(lbs) |
dimensions
(ODxH) |
working
pressure |
| CYL-1000 |
1000-lb tank |
3/4" |
360 |
30" x 58" |
260-psi |
| CYL-1000-LS |
1000-lb w/80% shut off switch |
3/4" |
360 |
30" x 58" |
260-psi |
| CYL-1000-QC |
1000-lb w/quick connects |
3/4" |
360 |
30" x 58" |
260-psi |
| CYL-1000-LS-QC |
1000-lb w/switch & quick connects |
3/4" |
360 |
30" x 58" |
260-psi |
| CYL-0250 |
250-lb tank |
3/4" |
86 |
16" x 44" |
260-psi |
| CYL-0250-LS |
250-lb w/80% shut off switch |
3/4" |
87 |
16" x 44" |
260-psi |
| CYL-0250-QC |
250-lb w/quick connects |
3/4" |
87 |
16" x 44" |
260-psi |
| CYL-0250-LS-QC |
250-lb w/switch & quick connects |
3/4" |
88 |
16" x 44" |
260-psi |
| CYL-0050 |
50-lb tank |
1/4" |
24 |
12.5" x 19" |
400-psi |
| CYL-0050-LS |
50-lb w/80% shut off switch |
1/4" |
25 |
12.5" x 19" |
400-psi |
| CYL-0030 |
30-lb tank |
1/4" |
16 |
9" x 18" |
400-psi |
| CYL-0030-LS |
30-lb w/80% shut off switch |
1/4" |
16 |
9" x 18" |
400-psi |
|