"We have experienced great results from the products we purchased from Reftec International, including the “Allvac” Recovery Unit and the “Minipurge” Portable Purge Unit! I have and will continue to refer others to Reftec. They offer a superior product, at a fair price, and back it with excellent customer support!"

Jeff Carver, President
Summit Refrigerants, Houston Texas

http://summitrefrigerants.com/

Category
Storage Tanks

Refrigerant Tanks: DOT Refrigerant Tanks, ASME Refrigerant Tanks

ASME Tanks

High capacity storage tanks accept complete high or low pressure refrigerant charges from large chillers. 
NEW sight glass windows replace sight glass tube (3/2003)

DOT Tanks

30, 50, 250, & 1000-lb capacities.   Optional low pressure switches available.  250 & 1000-lb tanks are retrofitted with full 3/4" service valves & copper dip tubes to meet capacity of commercial recovery units.

ASME Refrigerant Storage Tanks

  • Mounted on casters
  • High pressure (-HP) tanks: Dual 250-psi relief valves on diverting valve Low pressure (-LP) tanks: 250-psi rupture disc & 250-psi relief (meets ASME section VIII div 1 and ANSI specifications)
  • Pressure gauge
  • Three sight glass windows
  • 80% tank full float switch
  • Bottom drain connection
  • Liquid & Vapor ports: Threaded connections with isolation ball valves are supplied standard. Ball valves may be substituted with quick connect fittings on LP tanks only. 3/4” connections accomodate Lovac, Allvac, or Evac Commercial recovery units.
  • Options:
    • Cable for Liquid level cut out switch
    • Heating Bands for distillation
Part Number   Capacity   Ports Size / Connections   Pressure   Length   Height   Width
ASME-120-075-HP 120-gal 3/4" flare w/ball valves high 85.5-in 39-in 30-in
ASME-120-075-LP 120-gal 3/4" flare w/ball valves low 85.5-in 39-in 30-in
ASME-120-075-LP-QC 120-gal 3/4" flare w/quick connects low 85.5-in 39-in 30-in
ASME-250-075-HP 250-gal 3/4" flare w/ball valves high 94-in 42-in 30-in
ASME-250-075-LP  250-gal  3/4" flare w/ball valves  low  94-in  42-in  30-in
ASME-250-075-LP-QC  250-gal  3/4" flare w/quick connects  low  94-in  42-in  30-in
ASME-500-075-HP  500-gal  3/4" flare w/ball valves  high  113-in  49-in  37-in
ASME-500-075-LP  500-gal  3/4" flare w/ball valves  low  113-in  49-in  37-in
ASME-500-075-LP-QC  500-gal  3/4" flare w/quick connects  low  113-in  49-in  37-in
ASME-850-075-HP 850-gal 3/4" flare w/ball valves high 166-in 49-in 41-in
ASME-850-075-LP 850-gal 3/4" flare w/ball valves low 166-in 49-in 41-in
ASME-850-075-LP-QC 850-gal 3/4" flare w/quick connects low 166-in 49-in 41-in
ASME-1000-075-HP 1000-gal 3/4" flare w/ball valves high 192-in 49-in 52-in
ASME-1000-075-LP 1000-gal 3/4" flare w/ball valves low 192-in 49-in 52-in
ASME-1000-075-LP-QC 1000-gal 3/4" flare w/quick connects low 192-in 49-in 52-in

ASME Tank Refrigerant Capacity at 80% (in pounds):

Tank Model   Capacity   Dry Weight   R12   R22   R500   R502   R134A   R11   R123
ASME 120 120-gal 350-LB 1097 1000 1017 1020 1007 1230 1220
ASME 250  250-gal  650-LB  2195 2000 2034 2039 2015 2459 2440
ASME 500  500-gal  1200-LB  4390 4000 4068 4078 4030 4918 4880
ASME 850 850-gal 2040-LB 7463 6800 6915 6932 6851 8360 8926
ASME 1000 1000-gal 2400-LB 8780 8000 8136 8156 8060 9836 9760

DOT Refrigerant Recovery Tanks

  • Typical recovery tanks have small diameter ports that restrict refrigerant flow and decrease recovery rates. RefTec 250 & 1000-lb D.O.T. tanks have been fitted with full 3/4” service valves and copper dip tubes to eliminate restrictions and allow faster refrigerant transfer.
  • Tanks service R11, R12, R22, R113, R114, R123, R134a, & and additional high pressure refrigerants and blends.   For R410a, use only 30 & 50-lb tanks.
  • Quick connects are available for tanks servicing low pressure refrigerants.
  • Heating bands are available for distillation capabilities
Part Number Description Port Size (inch) Dry Weight (lbs) Dimensions (ODxH) Working Pressure
CYL-1000  1000-lb tank  3/4"  360 30" x 58"  260-psi
CYL-1000-LS  1000-lb w/80% shut off switch  3/4"  360 30" x 58"  260-psi
CYL-1000-QC  1000-lb w/quick connects  3/4"  360 30" x 58"  260-psi
CYL-1000-LS-QC  1000-lb w/switch & quick connects  3/4"  360 30" x 58"  260-psi
CYL-0250  250-lb tank  3/4"  86 16" x 44"  260-psi
CYL-0250-LS  250-lb w/80% shut off switch  3/4"  87 16" x 44"  260-psi
CYL-0250-QC  250-lb w/quick connects  3/4"  87 16" x 44"  260-psi
CYL-0250-LS-QC  250-lb w/switch & quick connects  3/4"  88 16" x 44"  260-psi
CYL-0050  50-lb tank  1/4"  24 12.5" x 19"  400-psi
CYL-0050-LS  50-lb w/80% shut off switch  1/4"  25 12.5" x 19"  400-psi
CYL-0030  30-lb tank  1/4"  16 9" x 18"  400-psi
CYL-0030-LS  30-lb w/80% shut off switch  1/4"  16 9" x 18"  400-psi
Category Items
Sort By  View 
ASME Tank
High capacity storage tanks accept complete high or low pressure refrigerant charges from large chillers.
ASME
DOT Cylinder
30, 50, 250, & 1000-lb capacities. Optional low pressure switches available. 250 & 1000-lb tanks are retrofitted with full 3/4" service valves & copper dip tubes to meet capacity of commercial recovery units.
CYL
Tank Scales
Integrated load cell tank scales for use with all types of tanks.
TNKSCALE
Powered by PDshop & Asp.Net